Omron winder inverter application software for RX and MX2
Omron winder inverter application software for RX and MX2
Based on established RX and MX2 inverter drive hardware, Omron’s winder application software includes dedicated winder functions such as diameter calculation without sensor, winder/unwinder bidirectional modes and tension control by either torque or PID.
Built-in winder functionality
The built-in programming functionality also offers a set of software libraries for winder and unwinder applications found in a variety of industries including: Printing; Packaging; Paper; Wire drawing, and Labelling industry
Winding is carried out through monitoring and controlling the position of a dancer roll, and adaptive motor control. As the dancer position fluctuates, the speed and torque of the motor are adjusted so that the material is wound/unwound cleanly and without breaking.
The RX inverter offers four times faster torque control loop. In addition to this torque control loop improvement, the solution includes dedicated application functions such as diameter calculation without sensor, winder/unwinder bidirectional modes and tension control by either torque or PID.
Application software libraries
Omron’s built-in programming functionality also offers a set of software libraries for a wider range of applications. In addition to PID and torque control for winders, it includes: Tower; Luffing; Grab and Gantry applications for cranes. Additionally, customers may also develop their own application software with the CX-Drive Programming open tool.
The CX-Drive Programming tool includes the standard CX-Drive software, and features flow chart and text editor programming languages. Five tasks with up to 0ne thousand lines of programming can be running simultaneously. There is also full access to parameters and inverter functions, and to an LCD real time clock.
Range features
| Features of MX2 | Features of RX |
| Power range up to 15 kW | Power range up to 132 kW |
| Torque control in open loop | Sensor-less and closed-loop vector control |
| 200% starting torque (at 0.5 Hz) | High starting torque in open loop (200% at 0.3 Hz |
| Double rating VT 120%/1 min and CT 150%/1 min | Full torque at 0 Hz in closed-loop |
| Models with IP54 housing protection | Double rating VT 120%/ 1 min and CT 150%/1 min |
| 24 VDC backup supply for control board and communication | Built-in application functionality: ELS (Electronic Line Shaft), brake control, load over speed control |
| Built-in application functionality (i.e. Brake control) |
See also Omron MX2 drives automate cable winding machines.